Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.498
Filtrar
1.
SAGE Open Med Case Rep ; 12: 2050313X241241191, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38559405

RESUMEN

New surgical techniques using narrow, tilted implants positioned through a magneto-dynamic tool in guided surgery for a Toronto restoration. A 69-year-old woman wanted fixed rehabilitation to replace her removable complete dentures. A cone-beam computed tomography showed significant bone resorption in both the maxillary and mandibular regions. The plan was to load the entire upper arch with six implants immediately, while removable partial dentures were recommended for the lower jaw. The guided surgery project was aligned with the new dentures, and the laboratory created a printed cast with dental implant analogues in planned positions. A metal-reinforced denture was constructed, and surgery was performed to place six narrow implants using the magneto-dynamic instrument. The denture was directly screwed onto multi-unit abutments. Final rehabilitation was completed after 6 months. Narrow implants can be a good option for fixed, full-arch rehabilitations. Further research is needed to confirm these findings on a larger scale.

2.
J Oral Implantol ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600837

RESUMEN

Various factors influence marginal bone loss following implant placement. This study explored the association between marginal bone loss and posterior implants positioned at different bone levels. Computer records and radiographs of patients with at least two adjacent implants were retrieved. Cases were categorized into non-splinted prosthesis and splinted prosthesis groups. Radiographic measurements were conducted at the time of abutment placement (T0), 1-3 years follow-up (T1), and the last visit (T2), measuring the vertical distance between adjacent implants. Multilevel linear regression models using generalized estimating equations were employed, with a significance level set at 5% (α=0.05). Fifty-six patient records were included, comprising 120 implants: 84 non-splinted (70%) and 36 splinted (30%). In the non-splinted group, marginal bone loss progression significantly depended on crestal height differences. For the mesial sides of posterior implants, marginal bone loss measured 1.0 ± 0.6 mm from T0 to T1, 2.4 ± 1.1 mm from T1 to T2, and 3.4 ± 1.2 mm from T0 to T2. Similarly, the distal sides of the most anteriorly placed implant exhibited marginal bone loss of 1.0 ± 0.7 mm from T0 to T1, 2.4 ± 1.0 mm from T1 to T2, and 3.5 ± 1.2 mm from T0 to T2. Non-splinted implants demonstrated a higher progression of marginal bone loss. This study suggests that non-splinted implants may lead to a more pronounced progression of marginal bone loss, particularly concerning crestal height differences, underscoring the need for further research.

3.
Quintessence Int ; 0(0): 0, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619260

RESUMEN

OBJECTIVES: This systematic review compares the impact of ball and locator attachments on marginal bone loss in implant-retained overdentures in completely edentulous patients. METHOD AND MATERIALS: Following PRISMA guidelines, health science librarians completed literature searches from inception to March 17, 2023 in seven databases. There were 15,686 items exported to EndNote from Embase.com, CINAHL (EBSCO), Cochrane Library, Ovid MEDLINE-ALL, PubMed, Scopus, and Web of Science. Hand-searching added four more articles. After deduplication, 6756 items were screened for eligibility. Twenty-nine studies were assessed by full text, of which ten studies, involving 424 subjects, were included in the review. Risk of bias assessment was conducted using the Cochrane Risk of Bias tool and the Newcastle Ottawa Scale. A meta-analysis was performed to synthesize and analyze the collective data from the selected studies. RESULTS: The included studies used diverse methodologies, implant systems, and loading protocols. Most studies reported no significant difference in marginal bone loss between ball and locator attachments. The meta-analysis revealed high heterogeneity. CONCLUSION: The results of this systematic review suggest that ball and locator attachments exhibit similar performance in terms of marginal bone loss in implant-retained overdentures. However, the limited number, risk of bias, and heterogeneity of studies highlight the need for standardized research designs and larger sample sizes in future investigations to draw more definitive conclusions.

4.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579114

RESUMEN

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Asunto(s)
Implantes Dentales , Torque , Pilares Dentales , Análisis del Estrés Dental , Retención de Prótesis Dentales , Diseño de Implante Dental-Pilar
5.
Trials ; 25(1): 267, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627819

RESUMEN

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Humanos , Anciano , Persona de Mediana Edad , Prótesis de Recubrimiento , Flujo de Trabajo , Mandíbula/cirugía , Satisfacción del Paciente , Impresión Tridimensional , Prótesis Dental de Soporte Implantado , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
J Mech Behav Biomed Mater ; 155: 106538, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38608345

RESUMEN

OBJECTIVES: An alternative option was proposed regarding the prosthetic rehabilitation of a fully edentulous mandible using only four implants. The aim was to reduce the stiffness of the prosthetic framework. To that end, the alternative option consists of a prosthetic framework optimized with a porous structure. Mechanical differences were analyzed between non-prosthetic mandible and restored mandible either with a conventional bulk titanium framework or with this alternative option. The non-prosthetic mandible corresponds to the mandible in its natural state, without prosthesis. This will be considered as the reference for comparison with restored models (mandible with prosthesis). METHODS: Three models are used: the first one is the non-prosthetic mandible, the second one is the restored mandible with conventional bulk titanium prosthetic framework, and the third one is the alternative option. Prosthetic framework was optimized with the use of a lattice structure. A numerical analysis was performed (with Abaqus Standard software®) to obtain the effective parameters corresponding to equivalent homogeneous behavior. In the 3 models, physiological boundary conditions were used, considering the activity of several muscles of the masticatory system during three main tasks of mastication (incisive clenching, maximum intercuspation and unilateral molar clenching). RESULTS: Numerical simulations allowed to obtain mandibular global kinematics, local displacement at the bone-implant interface and the state of strain at the bone-implant interface, for each masticatory tasks. For this comparative study, the non-prosthetic mandible model was used as a reference to observe the benefits of using a lattice prosthetic framework compared to a conventional bulk titanium framework. CONCLUSION: Compared to conventional titanium framework, the lattice prosthetic one appeared to be more respectful of the natural mandible kinematics, given by the reference model. It also resulted in strain values within the physiological loading range.

7.
J Dent ; 145: 104988, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38608832

RESUMEN

OBJECTIVES: This study aims to explore and discuss recent advancements in tooth reconstruction utilizing deep learning (DL) techniques. A review on new DL methodologies in partial and full tooth reconstruction is conducted. DATA/SOURCES: PubMed, Google Scholar, and IEEE Xplore databases were searched for articles from 2003 to 2023. STUDY SELECTION: The review includes 9 articles published from 2018 to 2023. The selected articles showcase novel DL approaches for tooth reconstruction, while those concentrating solely on the application or review of DL methods are excluded. The review shows that data is acquired via intraoral scans or laboratory scans of dental plaster models. Common data representations are depth maps, point clouds, and voxelized point clouds. Reconstructions focus on single teeth, using data from adjacent teeth or the entire jaw. Some articles include antagonist teeth data and features like occlusal grooves and gap distance. Primary network architectures include Generative Adversarial Networks (GANs) and Transformers. Compared to conventional digital methods, DL-based tooth reconstruction reports error rates approximately two times lower. CONCLUSIONS: Generative DL models analyze dental datasets to reconstruct missing teeth by extracting insights into patterns and structures. Through specialized application, these models reconstruct morphologically and functionally sound dental structures, leveraging information from the existing teeth. The reported advancements facilitate the feasibility of DL-based dental crown reconstruction. Beyond GANs and Transformers with point clouds or voxels, recent studies indicate promising outcomes with diffusion-based architectures and innovative data representations like wavelets for 3D shape completion and inference problems. CLINICAL SIGNIFICANCE: Generative network architectures employed in the analysis and reconstruction of dental structures demonstrate notable proficiency. The enhanced accuracy and efficiency of DL-based frameworks hold the potential to enhance clinical outcomes and increase patient satisfaction. The reduced reconstruction times and diminished requirement for manual intervention may lead to cost savings and improved accessibility of dental services.

8.
Artículo en Inglés | MEDLINE | ID: mdl-38498786

RESUMEN

Single implants are a predictable treatment, and immediate loading can be an option with acceptable survival rates. Clinical and patient-centered outcomes comparing immediate and delayed protocol of single implants are unclear. The purpose of this study was to assess complications, satisfaction, and quality of life of patients rehabilitated with delayed and immediate loading single crowns. An electronic search was conducted in PubMed/MEDLINE, Scopus, Web of Science, Cochrane Library, and Embase databases up to February 2023. Only prospective studies, randomized and non-randomized clinical trials comparing immediate and delayed loading were included. For the quantitative analysis, dichotomous and continuous variables were evaluated with a 95% confidence interval. A total of 20 studies were evaluated. No statistically significant difference between protocols was observed: satisfaction (I2: 0%; P = 0.42), quality of life (I2: 0 %; P = 0.05), biological complications (I2: 9%; P = 0.17) mechanical complications (I2: 58%; P = 0.84), and survival rate (I2: 0%; P = 0.38). Subgroup analysis showed significant differences only for marginal bone loss when immediate implants were placed in the mandible (IÇ: 15%; P = 0.01) and posterior zone (I2: 0%; P = 0.001). Complications and patient-centered outcomes for immediate single-implant crowns were comparable to delayed loading. Scientific evidence showed no significant difference between loading protocols for survival rates. Although several factors could interfere with the complication events, implant failures, and marginal bone loss, the subgroup analysis evidenced that only immediate implants placed in the posterior mandible zone had higher statistically significant mean marginal bone loss.

9.
J Prosthodont ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512962

RESUMEN

This report of four clinical cases aims to illustrate the use of a lateral implant as a solution for implant overdentures in the mandible in different clinical situations. The first two cases describe the clinical situations of patients wearing two-implant mandibular overdentures until the failure of one of the implants, one due to implant loss and the other due to a fracture of an abutment screw, and how the conditions were managed. The third case illustrates the placement of a single implant to retain an overdenture, where a midline implant, as originally planned, was not feasible due to anatomic reasons. The final case describes the use of a lateral implant to support and retain a single-implant mandibular overdenture. The four cases demonstrate that a single lateral implant can be utilized as sole retention in cases of a failing contra-lateral implant and as an alternative to a single implant in the midline.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38509032

RESUMEN

OBJECTIVE: This study aimed to explore the cross-sectional and prospective associations between self-reported functionality of complete dentures (FCD), satisfaction with complete dentures (SCD) and the ability to chew hard food (ACHF) on the one hand and the frailty index (FI) on the other hand among edentulous community-dwelling older Japanese people. METHODS: The study examined 770 edentulous participants of the Nihon University Japanese Longitudinal Study of Aging. The self-reported FCD, SCD and ability to chew six groups of food (from hardest to softest) with complete dentures were the independent variables at the baseline. The FI was computed including 40 deficits as the dependent variable at the baseline and 4 years later. Cross-sectional and prospective generalized linear regression models were fitted controlling for age, gender, marital status, education, working status and area of residence. RESULTS: The use of non-functional complete dentures and dissatisfaction with complete dentures were both associated with a higher FI cross-sectionally (3.9% [95% CI 2.2-5.6] and 3.2% [95% CI 1.5-4.9], respectively) and prospectively (3.9% [95% CI 2.0-6.0] and 3.3% [95% CI 1.3-5.3], respectively). Regarding the ability to chew, a higher FI at baseline was observed among those able to chew food of Group 2 (1.9%, [95% CI 0.1-3.7]) and Groups 4-6 (1.9%, [95% CI 0.1-3.7]), and a progressive increment in the FI, as the participants reported being able to chew softer groups of food at the follow-up (Group 2: 2.2% [95% CI 0.05-4.3]; Group 3: 3.6% [95% CI 1.2-6.0]; and Groups 4-6: 3.4 [95% CI 0.7-6.1]). CONCLUSION: Self-reported use of non-functional complete dentures, dissatisfaction with dentures and a reduced ACHF with complete dentures were associated with a higher FI both cross-sectionally and prospectively.

11.
J Clin Med ; 13(6)2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38541775

RESUMEN

Background: Short implants have been used in the restoration of edentulous jaws in the past several years. However, some studies have suggested that short implants are less successful than standard implants. The aim of this study is to investigate the outcome of short implants placed in the posterior maxilla or mandible following one-stage or immediate-function protocols with a follow-up of 7 years (clinically) and 5 years (radiographically). Methods: This study included 127 patients rehabilitated with 217 implants measuring 7 mm and supporting 157 fixed prostheses in the posterior segments of both jaws. Final abutments were delivered at the surgery stage and were loaded after 4 months in 116 patients (199 implants). The primary outcome measure was implant survival measured through life tables. Secondary outcome measures were marginal bone loss and the incidence of biological and mechanical complications at the patient level and implant level (evaluated through descriptive statistics). Results: Twenty-four patients (18.9%) with 45 implants (20.7%) were lost to the follow-up. In total, 32 implants failed (14.8%) in 22 patients (17.3%), resulting in a cumulative survival rate at 7 years of 81.2% for 7 mm implants in the rehabilitation of the posterior regions of the maxilla and mandible. The average (standard deviation) marginal bone loss was 1.47 mm (0.99 mm) at 5 years. The incidence rate of biological complications was 12.6% and 10.6% at the patient and implant levels, respectively. The incidence rate of mechanical complications was 21.3% for patients and 16.1% for implants. A higher failure rate was registered in smokers and in implant arrangements with a sequence of three fixtures in proximity. Conclusions: Within the limitations of this study, it can be concluded that the placement of 7 mm long implants for the partial implant-supported rehabilitation of atrophic posterior jaws is possible in the long term, judging by the survival rate and stable average marginal bone loss. Nevertheless, strict case selection should be performed, especially in smokers and with implant arrangements that provide a minimum of one unit in inter-implant distance.

12.
Biofouling ; 40(2): 114-129, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38538551

RESUMEN

This study aimed to answer the question formulated according to the PICO strategy: 'Which essential oils show antimicrobial activity against biofilms formed on dental acrylic resin?' composed by population (dental acrylic resin), intervention (application of essential oils), comparison (denture cleansers, antifungal drugs, chlorhexidine, and oral mouthwashes), and outcome (antibiofilm activity). In vitro experimental studies evaluating the activity of EOs on biofilm formed on acrylic resin were included. PRISMA guidelines were followed, and the search was performed in the PubMed, Science Direct, Embase, and Lilacs databases and in the gray literature using Google Scholar and ProQuest in December 2023. A manual search of the reference lists of the included primary studies was performed. Of the 1467 articles identified, 37 were selected for full-text reading and 12 were included. Twelve EOs were evaluated, of which 11 showed activity against Candida spp., 3 against Staphylococcus aureus, and 1 against Pseudomonas aeruginosa. The EOs of Cymbopogon citratus, Cinnamomum zeylanicum, and Cymbopogon nardus showed higher action than chlorhexidine, C. nardus higher than Listerine, C. citratus higher than nystatin, and Melaleuca alternifolia higher than fluconazole and nystatin. However, chlorhexidine was more effective than Lippia sidoides and Salvia officinalis, sodium hypochlorite was more effective than L. sidoides, nystatin was more effective than Zingiber officinale, Amphotericin B more effective than Eucalyptus globulus and M. alternifolia. In conclusion, the EOs of C. zeylanicum, C. citratus, C. nardus, and M. alternifolia showed antimicrobial activity to reduce biofilm on dental acrylic resin.


Asunto(s)
Resinas Acrílicas , Biopelículas , Aceites Volátiles , Antifúngicos/farmacología , Biopelículas/efectos de los fármacos , Candida albicans , Clorhexidina/farmacología , Nistatina/farmacología , Aceites Volátiles/farmacología
13.
Artículo en Inglés | MEDLINE | ID: mdl-38494409

RESUMEN

Zygomatic implants (ZI) are a valuable option for supporting an obturator prosthesis after maxillary resection. This study was performed to assess the clinical outcomes of a digitally validated guided technique for ZI placement, followed by immediate prosthetic obturation. The primary objective was to evaluate implant survival, while the secondary objective was to assess patient-reported quality of life post-rehabilitation. Twelve patients treated for head and neck cancer received a total of 36 ZI after ablative surgery. The mean duration of ZI follow-up was 30.1 months. The survival rate of ZI placed in non-irradiated patients was 100%, while it was 85% in irradiated patients. Patient-reported outcomes were evaluated using the Liverpool Oral Rehabilitation Questionnaire (LORQv3) and the University of Washington Quality of Life Questionnaire (UW-QOL v4). Most patients reported satisfactory outcomes in the oral function domain of the LORQv3 (mean score 17.7 ± 4.5; possible range 12-48, with lower scores indicating better outcomes). Regarding the UW-QOL v4, the swallowing and chewing domains had the highest scores (mean 97.5 ± 8.7 and 95.8 ± 14.4, respectively; maximum possible score of 100). In conclusion, this treatment approach improves function and quality of life after maxillary ablative surgery. However, irradiated patients showed a noticeable trend of higher implant failure, and this was influenced by tumour position and size impacting the radiation dose to the zygomatic bone.

14.
BMC Oral Health ; 24(1): 379, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38519932

RESUMEN

INTRODUCTION: Over the years, implant therapy has been a commonly used treatment option for individuals who are partially or totally edentulous, with a long-term success rate of over 90%. With significant advancements in biomaterials and technology, implant dentistry can now conduct prosthetic rehabilitations in the majority of patients catering to all types of needs. However, in order to meet the demands of a patient base that is always growing, new trends in implantology are emerging in recent years that are focused on minimally invasive surgery and financial sustainability. In certain clinical scenarios, connecting teeth and implants to support fixed partial prosthesis (FPPs) may be a predictable and workable course of treatment. MATERIALS AND METHODS: 22 patients were selected for this study who had tooth and implant supported prosthesis placed as a final restoration. Out of these 22 patients; 12 were male and 10 were female patients. Implants were placed following proper protocol and if grafting procedures were required they were carried out. A second stage surgical procedure was carried out and delayed loading protocols were followed. The statistical analysis was done using the IBM SPSS 24.0, Chicago, USA. The survival of the implants and teeth were measured by the Kaplan Meier survival scale. Bone loss was assessed at baseline(upon loading), 12 months and 24 months. RESULTS: The implant survival rate was measured at 6 months, 12 months, 18 months and 24 months. At 24 months, one implant showed failure, so the survival rate of the implants were 95.4%. Bone loss of 1 mm was seen around one implant at 12 months. Bone loss of 1 and 2 mm was present around two implants and one implant respectively at 24 months. CONCLUSION: From the results of this study, we can conclude that tooth implant supported prosthesis show very good survival when used in rehabilitation cases.


Asunto(s)
Pérdida de Hueso Alveolar , Implantes Dentales , Carga Inmediata del Implante Dental , Humanos , Masculino , Femenino , Implantes Dentales/efectos adversos , Estudios de Seguimiento , Implantación Dental Endoósea/métodos , Implantación Dental , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Resultado del Tratamiento , Diseño de Prótesis Dental , Pérdida de Hueso Alveolar/etiología
15.
BMC Oral Health ; 24(1): 355, 2024 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-38504246

RESUMEN

BACKGROUND: In partial edentulous individuals, a partial removable dental prosthesis (PRDP) is a common dental replacement option to improve oral function and quality of life. However, some patients discontinue using their denture over time. The aim of this study was to determine the prevalence and characteristics of partial edentulous patients who no longer wear their dentures, explore their reasons, and assess their oral health-related quality of life (OHRQoL). METHODOLOGY: This cross-sectional study, conducted at Chulalongkorn University Dental School from 2013 to 2019, involved patients who received PRDP treatment. They were contacted via phone calls and asked about their denture usage. Eligible participants were patients who had stopped or rarely used their PRDPs. Data on oral status, health insurance, and PRDP variables were collected from hospital records. Telephone interviews were conducted to collect the initial reasons for seeking PRDP treatment, reasons for discontinuation, desire for a new PRDP, and OHRQoL. The Oral Impacts on Daily Performances index was used to assess the OHRQoL. The score was dichotomized into the absence or presence of oral impacts. Chi-square tests and multivariable binary logistic regression were employed to determine the associations between oral impacts and various factors in the participants who discontinued PRDP usage. RESULTS: Among the 975 contacted participants, 175 (17.9%) discontinued using their PRDPs. Most of these individuals had at least 20 remaining natural teeth and/or 4 posterior occluding pairs. The primary initial reason for seeking PRDP treatment was often based on a dentist's suggestion. Although many participants reported no impact on OHRQoL and did not express the need for new PRDPs, those experiencing oral impacts were more likely to seek replacements. CONCLUSIONS: With up to 7 years follow-up duration, individuals with partial edentulism and sufficient remaining functional dentition without oral impacts were more inclined to discontinue PRDP usage. Those with maxillary anterior teeth loss were less likely to discontinue using their PRDP. The primary initial reason for seeking PRDP treatment was often a dentists' suggestion. However, the individuals reporting oral impacts expressed their needs for new denture replacements. This highlights the significance of incorporating patient needs and preferences in prosthodontic decision-making.


Asunto(s)
Prótesis Dental , Dentadura Parcial Removible , Boca Edéntula , Pérdida de Diente , Humanos , Calidad de Vida , Estudios Transversales , Estudios de Seguimiento , Salud Bucal
16.
J Contemp Dent Pract ; 25(1): 79-84, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514436

RESUMEN

AIM: This study aimed to investigate the effect of modified framework (MF) design on the fracture resistance of IPS e.max Press anterior single crown after thermocycling and cyclic loading. MATERIALS AND METHODS: Two types of IPS e.max Press frameworks were designed (n = 10); standard framework (SF) with a 0.5 mm uniform thickness and MF with a lingual margin of 1 mm in thickness and 2 mm in height connected to a proximal strut of 4 mm height and a 0.3 mm wide facial collar. The crowns were cemented to resin dies, subjected to 5,000 cycles of thermocycling, and loaded 10,000 cycles at 100 N. A universal testing machine was used to load specimens to fracture, and the modes of failure were determined. RESULTS: The mean and standard deviation (SD) of fracture resistance were 219.24 ± 110.00 N and 216.54 ±120.02 N in the SF and MF groups. Thus, there was no significant difference (p = 0.96). Mixed fracture was the most common failure mode in both groups. We found no statistically significant difference between the groups (p = 0.58). CONCLUSION: The MF design did not increase the fracture resistance of IPS e.max Press crown. CLINICAL SIGNIFICANCE: Framework design is an essential factor for the success of all-ceramic restorations and its modification might be regarded as an approach to increase fracture resistance. Furthermore, the modified design was evaluated in metal-ceramic or zirconia crowns while less attention was paid to the IPS e.max Press crowns. How to cite this article: Golrezaei M, Mahgoli HA, Yaghoobi N, et al. The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading. J Contemp Dent Pract 2024;25(1):79-84.


Asunto(s)
Porcelana Dental , Fracaso de la Restauración Dental , Coronas , Cerámica , Ensayo de Materiales , Análisis del Estrés Dental , Diseño Asistido por Computadora , Diseño de Prótesis Dental
17.
J Prosthodont Res ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38479890

RESUMEN

PURPOSE: Depression is a leading cause of disability. Although tooth loss increases the risk of depressive symptoms, it is unclear whether dental prosthesis use moderates this risk. This study aimed to investigate whether dental prosthesis use moderates the association between tooth loss and new depressive symptoms in older adults. METHODS: This cohort study used data from the 2016 and 2019 Japan Gerontological Evaluation Study (JAGES). The participants were independent older adults aged ≥65 years without depressive symptoms in 2016. The onset of depressive symptoms in 2019 was the outcome variable. The explanatory variables were dental status (≥20 teeth, 10-19 teeth with or without dental prostheses, and 0-9 teeth with or without dental prostheses) in 2016. Risk ratios (RRs) and 95% confidence intervals (CIs) were estimated using Poisson regression models with potential confounders as covariates. RESULTS: The analysis included 50,169 participants (mean age: 72.8 [standard deviation, 5.4] years). During follow-up, the incidence of depressive symptoms was 11.3%. Compared to those who had ≥20 teeth, the RR of depressive symptom onset was highest among those who had 0-9 teeth without dental prostheses (RR, 1.27; 95% CI, 1.04-1.56), after the adjustment for confounders. However, this risk was lower in those with 0-9 teeth and dental prostheses (RR, 1.08; 95% CI, 1.01-1.15). CONCLUSIONS: These data highlight the potential of dental prostheses as an important factor in reducing the risk of depressive symptoms among individuals with severe tooth loss.

18.
J Prosthodont ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38487989

RESUMEN

PURPOSE: The objective of this retrospective study was to evaluate the effect of the interproximal contour of single external hexagon implant restorations on the prevalence of peri-implantitis. MATERIAL AND METHODS: Records of 96 patients and 148 external hexagon (EH) implants with time in function ranging from 1 to 17 years were included in the study. The most recent clinical and radiographic data were collected from records and the prevalence of peri-implantitis was defined according to the 2017 World Workshop on the Classification of Periodontal and Peri-implant Diseases and Conditions. Marginal bone level (MBL), emergence angle (EA), emergence profile (EP), and crown/implant platform horizontal ratio (CIHR) were obtained from periapical radiographs. Dichotomous variables at the patient- and implant level were compared with association tests. Mann-Whitney U-Test was performed to compare continuous quantitative values between the studied groups. Binomial logistic regression was conducted to identify risk indicators associated with the peri-implantitis event at the patient- and implant level, with the significance level set at 5% for all tests. RESULTS: Nineteen patients (19.2%) and 24 implants (16.2%) with a mean time in function of 5.0 ± 4.7 years were classified as having peri-implantitis. No statistically significant differences concerning gender, mean age, implant location in the jaw, or time in function were observed between patients with or without peri-implantitis (p > 0.05). Of 24 implants with peri-implantitis 10 (41.7%) displayed EA ≤ 30° (16.4%) while 14 (58.3%) presented EA > 30° with no statistical difference between the groups (p > 0.05). No statistically significant associations were identified between EA, EP, or CIHR and the prevalence of peri-implantitis. CONCLUSION: The findings seem to indicate that the EA, EP, and CIHR of single restorations over external hexagon implants are not associated with the presence of peri-implantitis. However, prospective studies with larger samples are required to better ascertain such an association in the long term.

19.
J Prosthodont ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38409924

RESUMEN

PURPOSE: The objective was to determine the accuracy of 3D-printed dental models subjected to different storage conditions using six different material and printer combinations. MATERIALS AND METHODS: Three completely dentate models were designed using dental CAD software (3Shape Dental System). A horseshoe-shaped solid base with a posterior horizontal bar was used. The models were printed in a horizontal direction against the building platform without support. The models were printed using six printers with the corresponding recommended resin material: Carbon M2 (DPR10), HeyGears A2D4K (Model HP UV2.0), Stratasys J5 (MED610), Stratasys Origin One (DM200), Envision One (E-Model LightDLP), and Asiga Pro4K (VeriModel) with a standard layer thickness of 50 µm. All printed models underwent scanning using a laboratory scanner (Sirona inEOS X5) after printing. Subsequently, the models were randomly assigned into three groups of storage conditions, LT: cold environment (4 ± 1°C), HT: hot and dry environment (50 ± 2°C), and RT: room temperature (25 ± 2°C) serving as the control. Each group was kept under the designated condition and was scanned at 1, 2, 3, 4, and 8 weeks. The total number of models (N) was 72, with 6 printers producing 12 models per printer for 3 storage conditions, resulting in 4 models for each storage condition and each printer. The generated STL files were imported into a 3D inspection software for comparison with the original STL files. In-tolerance percentage, the deviation RMS, trueness, and precision were obtained and analyzed with least square mean linear regression using JMP Pro 15 to identify the significant effects (α = 0.05). RESULTS: The in-tolerance percentage as-printed was significantly different among different printers. Significant dimension deviations were observed after the first week of storage at HT and with subsequent weeks of storage. RT and LT did not show significant dimensional changes. Models printed with Carbon M2 showed the highest in-tolerance percentages compared to the other printers. CONCLUSIONS: The model deviations were affected by storage conditions and the printer used, with high-temperature storage showed least stability compared to low and room temperatures. No significant difference was observed between low and room temperature storage conditions. The Carbon M2 printer showed the highest accuracy among all printers tested. The region had a significant effect on the deviation measured, with the abutment body showing the least deviation. Among the 3D printers evaluated, A2D4K by HeyGears and Carbon M2 printers demonstrated the highest accuracy in terms of both precision and trueness.

20.
Gen Dent ; 72(2): 40-46, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38411484

RESUMEN

This in vitro study aimed to compare the color stability of temporary crowns fabricated by 3-dimensional (3D) printing with that of crowns fabricated with 2 manual methods. An impression was made of a prepared central incisor, from which 90 dies were fabricated. The dies were randomly assigned to 3 groups (n = 30) based on crown fabrication method: 3D printing, automix bis-acryl resin, or powder-and-liquid polymethyl methacrylate. All specimens were immersed in a coffee, soft drink, or distilled water solution for 1 week (n = 10 per subgroup). Color change was measured using a spectrophotometer and the International Commission on Illumination's CIE L*a*b* method, and the values were converted to the National Bureau of Standards (NBS) index for assessment and comparison. When color change was assessed according to fabrication method, the highest (mean [SD]) ΔE* value was reported for the automix specimens (3.39 [2.86]), and the lowest was recorded for the powder-and-liquid specimens (2.05 [2.33]) (P < 0.05; Kruskal-Wallis test). The difference between ΔE* values of the 3D printing group (2.46 [1.75]) and the powder-and-liquid group was not statistically significant. When color change was assessed according to the immersion solution, the coffee solution showed a significantly higher (mean [SD]) ΔE* value (5.04 [2.67]) than the soft drink (1.43 [0.92]) and distilled water (3.41 [7.93]) solutions (P < 0.05; Kruskal-Wallis test). The color changes associated with the 3 methods were statistically equal in terms of the NBS index ranges, most frequently falling in the range of very minor to acceptable change. The powder-and-liquid method seems to be most suitable for fabricating temporary prostheses for long-term use.


Asunto(s)
Resinas Acrílicas , Café , Humanos , Polvos , Impresión Tridimensional , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...